Find a Drug
Advanced Search

Professional

Miraluma

Drug Description
font size

DRUG DESCRIPTION

MIRALUMA®

Kit for the Preparation of Technetium Tc99m Sestamibi for Injection

FOR DIAGNOSTIC USE

DESCRIPTION

Each 5 mL vial contains a sterile, non-pyrogenic, lyophilized mixture of:

Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate - 1.0 mg Sodium Citrate Dihydrate - 2.6 mg L-Cysteine Hydrochloride Monohydrate - 1.0 mg Mannitol - 20 mg Stannous Chloride, Dihydrate, minimum (SnCl22H2O) - 0.025 mg Stannous Chloride, Dihydrate, (SnCl22H2O) - 0.075 mg

Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl22H2O) - 0.086 mg

Prior to lyophilization the pH is 5.3 to 5.9. The contents of the vial are lyophilized and stored under nitrogen.

This drug is administered by intravenous injection for diagnostic use after reconstitution with sterile, non-pyrogenic, oxidant-free Sodium Pertechnetate Tc99m Injection. The pH of the reconstituted product is 5.5 (5.0 - 6.0). No bacteriostatic preservative is present.

The precise structure of the technetium complex is Tc99m[MIBI]6+ where MIBI is 2-methoxy isobutyl isonitrile.

PHYSICAL CHARACTERISTICS

Technetium Tc99m decays by isomeric transition with a physical half-life of 6.02 hours1. Photons that are useful for detection and imaging studies are listed in Table 1.

Table 1. Principle Radiation Emission Data

Radiation

Mean %/Disintegration

Mean Energy (KeV)

Gamma -2

89.07

140.5

1Kocher, David, C., Radioactive Decay Data Tables, DOE/TIC-11026, 108(1981).

 

EXTERNAL RADIATION

The specific gamma ray constant for Tc99m is 5.4 microcoulombs/Kg-MBq-hr (0.78R/mCi-hr) at 1 cm. The first half value layer is 0.017 cm of Pb. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. To facilitate control of the radiation exposure from Megabequerel (millicurie) amounts of this radionuclide, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of 1,000.

Table 2. Radiation Attenuation by Lead Shielding

Shield Thickness (Pb) cm

Coefficient of Attenuation

0.017

0.5

0.08

10-1

0.16

10-2

0.25

10-3

0.33

10-4

To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 3.

Table 3. Physical Decay Chart; Tc99m Half-Life 6.02 Hours

Hours

Fraction Remaining

Hours

Fraction Remaining

0*

1.000

8

.398

1

.891

9

.355

2

.794

10

.316

3

.708

11

.282

4

.631

12

.251

5

.562

   

6

.501

   

7

.447

   

*Calibration Time

Brand Name: Miraluma
Generic Name: Technetium Tc99m sestamibi
Bookmark this page:



Women's Health

Find out what women really need.

WebMD Symptom Checker - Start Here Ringworm Slideshow: Watch and Learn

3D Mammogram3D Mammogram
Learn how new technology may change the way breast cancer is diagnosed and in turn, save more lives. See more WebMD Videos »