Dextrose / Electrolytes No. 48

Baxter
5% Dextrose and Electrolyte No. 48 Injection
(Multiple Electrolytes and Dextrose Injection, Type 1, USP)
in AVIVA Plastic Container

DRUG DESCRIPTION

5% Dextrose and Electrolyte No. 48 Injection (Multiple Electrolytes and Dextrose Injection, Type 1, USP) is a sterile, nonpyrogenic solution for fluid and electrolyte replenishment and caloric supply in a single dose container for intravenous administration. Each 100 mL contains 5 g Dextrose Hydrous,

USP*, 260 mg Sodium Lactate (C3H5NaO3), 141 mg Potassium Chloride, USP (KCl), 31mg Magnesium Chloride, USP (MgCl2·6H20), 20 mg Monobasic Potassium Phosphate, NF (KH2PO4), and 12 mg Sodium Chloride, USP (NaCl). It contains no antimicrobial agents. pH 5.0 (4.0 to 6.5).

D-Glucopyranose monohydrate

5% Dextrose and Electrolyte No. 48 Injection (Multiple Electrolytes and Dextrose Injection, Type 1, USP) administered intravenously has value as a source of water, electrolytes, and calories. One liter has an ionic concentration of 25 mEq sodium, 20 mEq potassium, 3 mEq magnesium, 24 mEq chloride, 23 mEq lactate and 3 mEq phosphate as HPO4=. The osmolarity is 348 mOsmol/L (calc). Normal physiologic osmolarity range is approximately 280 to 310 mOsmol/L. Administration of substantially hypertonic solutions (≥600 mOsmol/L) may cause vein damage. The caloric content is 180 kcal/L.

The flexible container is made with non-latex plastic materials specially designed for a wide range of parenteral drugs including those requiring delivery in containers made of polyolefins or polypropylene. For example, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of paclitaxel. In addition, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of all drugs deemed compatible with existing polyvinyl chloride container systems. The solution contact materials do not contain PVC, DEHP, or other plasticizers.

The suitability of the container materials has been established through biological evaluations, which have shown the container passes Class VI U.S. Pharmacopeia (USP) testing for plastic containers. These tests confirm the biological safety of the container system.

The flexible container is a closed system, and air is prefilled in the container to facilitate drainage. The container does not require entry of external air during administration.

The container has two ports: one is the administration outlet port for attachment of an intravenous administration set and the other port has a medication site for addition of supplemental medication (See Directions for Use). The primary function of the overwrap is to protect the container from the physical environment.

Last reviewed on RxList: 12/27/2005
This monograph has been modified to include the generic and brand name in many instances.

A A A

Report Problems to the Food and Drug Administration

 

You are encouraged to report negative side effects of prescription drugs to the FDA. Visit the FDA MedWatch website or call 1-800-FDA-1088.


Weight Loss Wisdom

Get tips, recipes and inspiration.

Related Supplements
advertisement
advertisement
Use Pill Finder Find it Now See Interactions

Pill Identifier on RxList

  • quick, easy,
    pill identification

Find a Local Pharmacy

  • including 24 hour, pharmacies

Interaction Checker

  • Check potential drug interactions
Search the Medical Dictionary for Health Definitions & Medical Abbreviations