Recommended Topic Related To:

Plasma-Lyte 148d5

"Jan. 16, 2013 -- The Center for Science in the Public Interest (CSPI) has announced its seventh annual Xtreme Eating Awards, and as usual, there are some eye-popping, belt-busting, and artery-clogging stats behind these oversized restaurant meals"...

Plasma-Lyte 148 and 5% Dextrose Injection

PLASMA-LYTE 148 and 5% Dextrose Injection
(Multiple Electrolytes and Dextrose Injection, Type 1, USP) in AVIVA Plastic Container

DRUG DESCRIPTION

PLASMA-LYTE 148 and 5% Dextrose Injection (multiple electrolytes and dextrose injection) (Multiple Electrolytes and Dextrose Injection, Type 1, USP) is a sterile, nonpyrogenic solution for fluid and electrolyte replenishment and caloric supply in a single dose container for intravenous administration. Each 100 mL contains 5 g Dextrose Hydrous, USP*, 526 mg Sodium Chloride, USP (NaCl); 502 mg Sodium Gluconate (C6H11NaO7); 368 mg Sodium Acetate Trihydrate, USP (C2H3NaO2•3H2O), 37 mg Potassium Chloride, USP (KCl); and 30 mg Magnesium Chloride, USP (MgCl2•6H2O). It contains no antimicrobial agents. The pH is 5.0 (4.0 to 6.5). The pH is adjusted with hydrochloric acid.

PLASMA-LYTE 148 and 5% Dextrose Structural Formula Illustration

D-Glucopyranose monohydrate

PLASMA-LYTE 148 and 5% Dextrose Injection (Multiple Electrolytes and Dextrose Injection, Type 1, USP) administered intravenously has value as a source of water, electrolytes, and calories. One liter has an ionic concentration of 140 mEq sodium, 5 mEq potassium, 3 mEq magnesium, 98 mEq chloride, 27 mEq acetate and 23 mEq gluconate. The osmolarity is 547 mOsmol/L (calc). Normal physiologic osmolarity range is approximately 280 to 310 mOsmol/L. Administration of substantially hypertonic solutions ( > 600 mOsmol/L) may cause vein damage. The caloric content is 190 kcal/L.

The flexible container is made with non-latex plastic materials specially designed for a wide range of parenteral drugs including those requiring delivery in containers made of polyolefins or polypropylene. For example, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of paclitaxel. In addition, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of all drugs deemed compatible with existing polyvinyl chloride container systems. The solution contact materials do not contain PVC, DEHP, or other plasticizers.

The suitability of the container materials has been established through biological evaluations, which have shown the container passes Class VI U.S. Pharmacopeia (USP) testing for plastic containers. These tests confirm the biological safety of the container system.

The flexible container is a closed system, and air is prefilled in the container to facilitate drainage. The container does not require entry of external air during administration.

The container has two ports: one is the administration outlet port for attachment of an intravenous administration set and the other port has a medication site for addition of supplemental medication (See Directions for Use). The primary function of the overwrap is to protect the container from the physical environment.

Last reviewed on RxList: 3/6/2009
This monograph has been modified to include the generic and brand name in many instances.

A A A

Report Problems to the Food and Drug Administration

 

You are encouraged to report negative side effects of prescription drugs to the FDA. Visit the FDA MedWatch website or call 1-800-FDA-1088.


Weight Loss Wisdom

Get tips, recipes and inspiration.

advertisement
advertisement
Use Pill Finder Find it Now See Interactions

Pill Identifier on RxList

  • quick, easy,
    pill identification

Find a Local Pharmacy

  • including 24 hour, pharmacies

Interaction Checker

  • Check potential drug interactions
Search the Medical Dictionary for Health Definitions & Medical Abbreviations