Recommended Topic Related To:

Plasma-Lyte R

"As required by the bipartisan FDA Food Safety Modernization Act (FSMA), the U.S. Food and Drug Administration today proposed a rule that would require the largest food businesses in the United States and abroad to take steps to prevent facilities"...

PlasmaLyte R

PLASMA-LYTE R INJECTION
(Multiple Electrolytes Injection, Type 2, USP) in AVIVA Plastic Container

DRUG DESCRIPTION

PLASMA-LYTE R Injection (Multiple Electrolytes Injection, Type 2, USP) is a sterile, nonpyrogenic isotonic solution in a single dose container for intravenous administration. Each 100 mL contains 640 mg of Sodium Acetate Trihydrate, USP (C2H3NaO2• 3H2O); 496 mg of Sodium Chloride, USP (NaCl); 89.6 mg of Sodium Lactate (C3H5NaO3); 74.6 mg of Potassium Chloride, USP (KCl); 36.8 mg of Calcium Chloride, USP (CaCl2• 2H2O); and 30.5 mg of Magnesium Chloride, USP (MgCl2•6H2O). It contains no antimicrobial agents. The pH is adjusted with hydrochloric acid. The pH is 5.5 (4.0 to 8.0).

PLASMA-LYTE R Injection (Multiple Electrolytes Injection, Type 2, USP) administered intravenously has value as a source of water, electrolytes, and calories. One liter has an ionic concentration of 140 mEq sodium, 10 mEq potassium, 5 mEq calcium, 3 mEq magnesium, 103 mEq chloride, 47 mEq acetate, and 8 mEq lactate. The osmolarity is 312 mOsmol/L (calc). Normal physiologic osmolarity range is approximately 280 to 310 mOsmol/L. Administration of substantially hypertonic solutions may cause vein damage. The caloric content is 11 kcal/L.

The flexible container is made with non-latex plastic materials specially designed for a wide range of parenteral drugs including those requiring delivery in containers made of polyolefins or polypropylene. For example, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of paclitaxel. In addition, the AVIVA container system is compatible with and appropriate for use in the admixture and administration of all drugs deemed compatible with existing polyvinyl chloride container systems. The solution contact materials do not contain PVC, DEHP, or other plasticizers.

The suitability of the container materials has been established through biological evaluations, which have shown the container passes Class VI U.S. Pharmacopeia (USP) testing for plastic containers. These tests confirm the biological safety of the container system.

The flexible container is a closed system, and air is prefilled in the container to facilitate drainage. The container does not require entry of external air during administration.

The container has two ports: one is the administration outlet port for attachment of an intravenous administration set and the other port has a medication site for addition of supplemental medication (See Directions for Use). The primary function of the overwrap is to protect the container from the physical environment.

Last reviewed on RxList: 3/5/2009
This monograph has been modified to include the generic and brand name in many instances.

A A A

Report Problems to the Food and Drug Administration

 

You are encouraged to report negative side effects of prescription drugs to the FDA. Visit the FDA MedWatch website or call 1-800-FDA-1088.


Weight Loss Wisdom

Get tips, recipes and inspiration.


From WebMD